Airy Technology P230
AIRY P230

 

Airy Technology P230

Channel Sizes 0.3 µm and 0.5 µm
Counting Efficiency 50% at 0.3 μm; 100% for particles > 0.45 μm (per JIS)
Concentration Limit 2,000,000 particles / ft3 at 5% coincidence loss
Light Source Long Life Laser Diode
Zero Count Level <1 count / 5 minutes (per JIS B9921)
Size Resolution <15% at 0.5 μm (per ISO 21501-4)
Flow Rate 0.1 CFM (2.83 LPM)
Flow Control Critical orifice
Vacuum Requirements External vacuum >15” (38.1 cm) of Hg
Calibration NIST traceable
Sample Probe/Tubing Isokinetic sampling probe
Communication Interface Modbus™ RTU or Modbus™ ASCII outputs (specified upon order)
Power 9-30 VDC
Dimensions (L x W x H) 1.8” x 3.7“ x 1.5” (4.5 cm x 9.3 cm x 3.8 cm) does not include probes
Weight 0.62 lb (0.28 kg)
Standards ISO 21501-4 and JIS B9921
Warranty 2 year limited warranty
Operating Conditions 5° to 35°C 20% to 95%RH non-condensing
Storage Conditions -20° to 50°C Up to 98%RH non-condensing
Included Accessories User manual
Optional Accessories Purge filter, data cable, vacuum and sample tubing, Isokinetic sampling probe

 

AIRY TECHNOGLOGY SINGAPORE, MALAYSIA, INDONESIA DISTRIBUTOR

 

Airy Technology P231
P231
Channel Sizes 0.5 µm and 5.0 µm
Counting Efficiency 50% at 0.5 μm; 100% for particles > 0.75 μm (per JIS)
Concentration Limit 500,000 particles / ft3 at 5% coincidence loss
Light Source Long Life Laser Diode
Zero Count Level <1 count / 5 minutes (per JIS B9921)
Size Resolution <15% at 0.7 μm (per ISO 21501-4)
Flow Rate 1.0 CFM (28.3 LPM)
Flow Control Critical orifice
Vacuum Requirements External vacuum >15” (38.1 cm) of Hg
Calibration NIST traceable
Sample Probe/Tubing Isokinetic sampling probe
Communication Interface Modbus™ RTU or Modbus™ ASCII outputs (specified upon order)
Power 9-30 VDC
Dimensions (L x W x H) 1.8” x 3.7“ x 1.5” (4.5 cm x 9.3 cm x 3.8 cm) does not include probes
Weight 0.62 lb (0.28 kg)
Standards ISO 21501-4 and JIS B9921
Warranty 2 year limited warranty
Operating Conditions 5° to 35°C 20% to 95%RH non-condensing
Storage Conditions -20° to 50°C Up to 98%RH non-condensing
Included Accessories User manual
Optional Accessories Purge filter, data cable, vacuum and sample tubing, Isokinetic sampling probe

 

AIRY TECHNOLOGY SINGAPORE, MALAYSIA, INDONESIA DISTRIBUTOR

AIRY TECHNOLOGY P311
AIRY P311

 

AIRY TECHNOLOGY P311

Size Range 0.3 to 5.0 μm
Channel Sizes Channel 1: 0.3/0.5 μm; Channel 2: 0.5/1.0/2.0/2.5 μm; Channel 3: 5.0 μm
Counting Efficiency 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
Concentration Limit 4,000,000 Particles/ft³ @ 5% coincidence loss
Light Source Long Life Laser Diode
Zero Count Level <1 count / 5 minutes (<2 particles / ft³) (per ISO 21501-4 & JIS)
Size Resolution <15% at 0.5 μm (per ISO 21501-4)
Flow Rate 0.1 CFM (2.83 LPM)
Flow Rate Control Automatic flow control
Calibration NIST traceable
Sample Probe/Tubing Isokinetic sampling probe and probe for tubing
Sampling Modes Manual, automatic, ISO¹, cumulative, differential, count/concentration
Sampling Time 1 second to 99 minutes 59 seconds (configurable)
Sampling Frequency 1 to 1,999 cycles or continuous (configurable)
Sample Output Internal HEPA filter
Vacuum Source Internal Pump
Communication Interface USB
Data Storage 8,000 sample records
Display 3.5″ (8.9 cm) 320 x 240 Color LCD
Power DC 5V 1A (Mini USB TYPE-B)
Battery Removable AA Ni-MH
Dimensions (L x W x H) 7” x 3.5” x 1.9” (17.8 cm x 9 cm x 4.7 cm) does not include probes
Weight 1.26 lb (.57 kg)
Standards ISO 21501-4 and JIS B9921
Warranty 1 year limited warranty
Operating Conditions 5° to 35° C 20% to 95%RH non-condensing
Storage Conditions -20° to 50° C 20% Up to 98%RH non-condensing
Accessories Operating manual on CD, AC adapter, isokinetic inlet, USB cable, purge filter, data download software, 4 x AA batteries with charger, calibration certificate, carrying case.
Optional Accessories Barbed fitting hose adapter

 

AIRY TECHNOGLOGY SINGAPORE, MALAYSIA, INDONESIA DISTRIBUTOR

 

AIRY TECHNOLOGY P611
AIRY P611

 

AIRY TECHNOLOGY P611

Size Range 0.3 to 10.0 μm
Channel Sizes Standard: 0.3, 0.5, 0.7, 1.0, 2.0, 5.0 μm
Standard: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 μm
Standard: 0.3, 0.5, 0.7, 1.0, 2.5, 5.0 μm
Standard: 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm
Optional: additional size channels available
Counting Efficiency 50% @ 0.3 μm; 100% for particles >0.45 μm per JIS
Concentration Limit 4,000,000 Particles/ft³ @ 5% coincidence loss
Light Source Long Life Laser Diode
Zero Count Level <1 count / 5 minutes (<2 particles / ft³) (per ISO 21501-4 & JIS)
Size Resolution <15% at 0.5 μm (per ISO 21501-4)
Flow Rate 0.1 CFM (2.83 LPM)
Flow Rate Control Automatic flow control
Calibration NIST traceable
Sample Probe/Tubing Isokinetic sampling probe and probe for tubing
Sampling Modes Manual, automatic, ISO¹, GMP², cumulative, differential, count/concentration
Reports ISO 14644-1 and EU GMP
Sampling Time 1 second to 99 minutes 59 seconds (configurable)
Sampling Frequency 1 to 9999 cycles or continuous (configurable)
Sample Output Internal HEPA filter
Vacuum Source Internal Pump
Communication Interface USB
Data Storage 10,000 sample records
Security 2-level password protection
Alarm Counts, low battery, flow and laser status
Display 3.5″ (8.9 cm) 320 x 240 Color LCD
Power DC 5V 1A (Mini USB TYPE-B)
Battery Removable AA Ni-MH
Environmental Sensors Optional temperature/humidity probe
Dimensions (L x W x H) 7” x 3.5” x 1.9” (17.8 cm x 9 cm x 4.7 cm) does not include probes
Weight 1.26 lb (.57 kg)
Standards ISO 21501-4 and JIS B9921
Warranty 2 year limited warranty
Operating Conditions 5° to 35° C 20% to 95%RH non-condensing
Storage Conditions -20° to 50° C 20% Up to 98%RH non-condensing
Accessories Operating manual on CD, AC adapter, isokinetic inlet, USB cable, purge filter, data download software, 4 x AA batteries with charger, calibration certificate, carrying case.
Optional Accessories Temperature/Humidity probe, barbed fitting hose adapter

 

AIRY TECHNOGLOGY SINGAPORE, MALAYSIA, INDONESIA DISTRIBUTOR

ARIZONA MOISTURE & DOLIDS ANALYZER
COMPUTRAC MAX 4000XL

ARIZONA INSTRUMENT 

COMPUTRAC MAX 4000XL

DELTALAB 1-200UL YELLOW TIPS BEVELLED
200016

DELTALAB 200016 1-200UL YELLOW TIPS BEVELLED

MOQ: 25X1000PCS/CS

DET-TRONICS UD10 UNIVERSAL DISPLAY FOR CGS
UD10S5M25W2C

UD10 UNIVERSAL DISPLAY FOR CGS
Model : UD10S5M25W2C
P/N: 010254 - 003

Display : LCD Backlit
Analog Output : 4 - 20mAdc with Hart Relay Output : 3 x Alarm Relays, 1 x Fault Relay
Power Supply : 18 - 30Vdc
Housing Material : SS316 (CF8M) Ingress Protection : IP66
Cable Entry : 5 x M25
Classification : EEx d IIC T6
Class 1 Div 1 Groups B, C & D Approval : FM/CSA/ATEX/IECEx
c/w
Accessories consisting of :
* 1 no. SS316, 2" Pipe Mount Bracket c/w U‐Bolts and nuts
* 3 nos. Plug, M25, Brass nickel Plated, Exde
* 1 no. SS316 nametag plate c/w Steel wire
* 1 x Reducer, M25 to M20, Brass Nickel Plated
DET-TRONICS

ENERCON INDUCTION CAP SEALER
SUPER SEAL 75

DEEP TUNNEL SEALING HEAD LM4033-130

ENERCON SINGAPORE

 

FESTO
VMPA1-M1H-M-PI

FESTO VMPA1-M1H-M-PI  SOLENIOD VALVE

SGD114.5
HIOKI AC AUTOMATIC INSULATION
3174

HIOKI AC AUTOMATIC INSULATION/WITHSTANDING HiTESTER 3174

Testing voltage

0.2 V AC to 5.00 kV AC

Voltage setting

Digital setting, Setting resolution: 0.01 kV

Waveform/Frequency

Sine wave (Distortion ratio 5 % or less at no load), 50/60 Hz selectable

Current measurement

0.01 mA to 20.0 mA, True RMS rectified (digital display)

Measurement range

10 mA (0.01 mA resolution), 20 mA (0.1 mA resolution)

Voltage meter

Accuracy: ±1.5 % rdg. (1000 V or more), ±15 V (less than 1000 V), True RMS rectified

Judgment function

Window comparator method (Digital setting)

[Insulation test section]

 

Testing voltage

500 V DC, 1000 V DC

Unloaded voltage

1 to 1.2 times rated voltage

Rated testing current

1 to 1.2 mA, Shorted current: 4 to 5 mA (at 500 V), 2 to 3 mA (at 1000 V)

Measurement range, Accuracy

0.5 MΩ to 999 MΩ (at 500 V), and 1 MΩ to 999 MΩ (at 1000 V): ±4 % rdg.,

1000 MΩ to 2000 MΩ: ±8 % rdg.

Judgment function

Window comparator method (Digital setting)

[Timer section]

*Test times may differ from set timer times depending on the load.

Setting range

0.3 to 999 s

Ramp, Delay

Testing voltage ramp-up, or down, Insulation test delay: 0.1 to 99.9 s

[General section]

 

Functions

Saving 8 testing conditions, hold, buzzer, contact check

Monitor function

Output voltage, detected current, insulation resistance, Refresh rate: 4 times/s

Power supply

100 to 240 V AC, (50/60 Hz), 200 VA max.

Dimensions and mass

320 mm (12.60 in)W × 155 mm (6.10 in)H × 395 mm (15.55 in)D, 15 kg (529.1 oz)

Accessories

H.V. Test lead 9615 (high voltage side and return, 1 each) ×1, Power cord ×1, Instruction manual ×1, Disconnection prevention plate ×1

 

HIOKI SINGAPORE DISTRIBUTOR

 

SGD5570
HIOKI AC CURRENT SENSOR
CT7126

HIOKI AC CURRENT SENSOR

HIOKI CT7126

HIOKI SINGAPORE DISTRIBUTOR

SGD273
HIOKI AC CURRENT SENSOR
CT7131

HIOKI AC CURRENT SENSOR

HIOKI CT7131

HIOKI SINGAPORE DISTRIBUTOR

SGD273
HIOKI AC CURRENT SENSOR
CT7136

HIOKI AC CURRENT SENSOR

HIOKI CT7136

 

HIOKI SINGAPORE DISTRIBUTOR

SGD303
HIOKI AC FLEXIBLE CURRENT SENSOR
CT7044

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

  CT7046 CT7045 CT7044
Rated measurement current 6000 A AC
Internal Measurement range 600A AC/ 6000A AC (Range is controlled by main device)
Max. allowable input 10000 A continuous (at 6000 A range, 45 to 66 Hz, requires derating )
Bandwidth 10 Hz to 50 kHz (±3dB)
Amplitude and phase accuracy ±1.5 % rdg. ±0.25 % f.s. (f.s. is internal range, 45 to 66 Hz) ±1 deg
Output rate 1 mV/A (600 A*), 0.1 mV/A (6000 A)
*Selectable only when used with CM7290, CM7291, PQ3100
Max. rated voltage to earth AC 600 V (CAT IV), AC 1000 V (CAT III)
Loop diameter φ 254 mm (10.00 in) or less φ 180 mm (7.09 in) or less φ 100 mm (3.94 in) or less
Dustproof, waterproof IP54* (When sensor is connected to a compatible instrument.) * Do not use when wet.
Output connectors HIOKI PL 14
Operating temperature range -25 °C to 65 °C (-13 °F to 149 °F)
Dimensions Flexible loop cable diameter: φ7.4 mm (0.29 in), Cable length: Between flexible loop and battery box: 2.3 m (7.55 ft), Output cable: 20 cm (0.66 ft), Battery box25 mm (0.98 in)W × 72 mm (2.83 in)H × 20 mm (0.79 in)D
Mass 186 g (6.6 oz) 174 g (6.1 oz) 160 g (5.6 oz)
Accessories Instruction manual ×1

 

Model No. (Order Code)

CT7046

6000 A, φ254 mm (10.00 in)

CT7045

6000 A, φ180 mm (7.09 in)

CT7044

6000 A, φ100 mm (3.94 in)

HIOKI CT7044, CT7045, CT7046

HIOKI SINGAPORE DISTRIBUTOR

 

SGD379
HIOKI AC FLEXIBLE CURRENT SENSOR (Dia: 100mm)
CT9667-01

HIOKI CT9667-01

 

CT9667-01

CT9667-02

CT9667-03

Rated input current

5000 A AC/ 500 A AC

Max. allowable input

10000 A continuous (45 to 66 Hz, requires derating at frequency)

Bandwidth

10 Hz to 20 kHz (±3dB)

Amplitude and phase accuracy

±2 % rdg. ±0.3 % f.s. (45 to 66 Hz, at center of flexible loop)

Phase: ±1 deg (45 to 66 Hz)

Output voltage

500 mV AC/f.s. (0.1 mV AC/A) at 5000 A range

500 mV AC/f.s. (1 mV AC/A) at 500 A range

Max. rated voltage to earth

1000 V AC (CAT III), 600 V AC (CAT IV)

Core diameter

φ 100 mm (3.94 in)

φ 180 mm (7.09 in)

φ 254 mm (10.00 in)

Output terminal

BNC

Operating temperature

-25 °C to +65 °C

(-13 °F to 149 °F)

-25 °C to +65 °C

(-13 °F to 149 °F)

-10 °C to +50 °C

(14 °F to 122 °F)

Power supply

LR6 (AA) alkaline batteries ×2, Continuous use : 7 days (rated power 35 mVA), or AC adapter 9445-02/-03 (rated power 0.2 VA), or External power supply 5 to 15 V DC (rated power 0.2 VA)

Dust and water resistance

Flexible loop only: IP54

* Do not use when wet.

N/A

Dimensions and mass

Flexible loop cable diameter: φ7.4 mm (0.29 in), 

Cable length: Between flexible loop and battery box: 2 m (6.56 ft), 

Output cable: 1 m (3.28 ft), Battery box: 35 mm (1.38 in)W × 120.5 mm (4.74 in)H × 34 mm (1.34 in)D, 280 g (9.9 oz)

Flexible loop cable diameter: φ13 mm (0.51 in), Cable length: Between flexible loop and battery box: 2 m (6.56 ft), Output cable: 1 m (3.28 ft)

Battery box: 35 mm (1.38 in)W × 120.5 mm (4.74 in)H × 34 mm (1.34 in)D, 470 g (16.6 oz)

Accessories

LR6 (AA) alkaline batteries ×2, Instruction manual ×1

 

HIOKI SINGAPORE DISTRIBUTOR

 

SGD606
Showing 1 to 15 of 139 (10 Pages)
About US
  • TAKEIKI PTE LTD IS A DYNAMIC AND FAST GROWING COMPANY. WE DISTRIBUTE WELL KNOW BRANDS INDUSTRIAL AUTOMATION PRODUCTS. AND ALSO PROVIDES INCLUDES FABRICATION, PRECISION ENGINEERING, VISION AND PLC PROGRAMMING BESIDES THE MRO (MAINTENANCE, REPAIR AND OPERATING SUPPLIES).
Information
Delivery Information

  • All will be self-collect, ex-work Takeiki unless specify in the quotation.
Quality Policy

Takeiki is committed in providing the highest service level and ensuring products from manufacturers' free from visual defects.

To achieve the above through:

  • Doing things right the first time
  • Consistently meet or exceed customer's expectations in service level.
  • Continuous improvements in service and performance
  • Perform visual inspections and photos upon receipt
Terms and Conditions
Customer Service
Locate US
Takeiki Pte Ltd, 280 Woodlands Industrial Park E5, #06-43/44, Singapore 757322

+65 6286 7312
sales@takeiki.net